H Advantage
Your location: Home> High pressure hydrogen storage test> SUS Laboratory> Cooling module test bench> Details

Cooling module test bench

 

Device Details

Equipment name: Cooling module test bench
Equipment function: Simulate fuel cell stack output performance simulation, radiator heat dissipation simulation
Equipment parameters:
Pump performance: flow rate 0~200L/min, pressure 0~3bar, temperature -50 ℃~150 ℃;
Heater: flow rate 0~20L/min, temperature -50 ℃~150 ℃;
Simulated stack output power: 20~100kW;
Stack outlet: flow rate 0~150L/min, pressure 0~1.5bar, temperature room temperature~90 ℃, pressure drop 0~1000mbar;
Applicable products: Fuel cell cooling module
Test project:
Functional verification test of fuel cell cooling module
Performance verification test of fuel cell radiator