Device Details

Equipment Name: Fuel Cell Unit Testing Station
Equipment function: Development, performance testing, evaluation, and research of fuel cell single cells/membrane electrodes
Equipment parameters: Power upper limit: 500W, Current upper limit: 150A, Voltage upper limit: 50VDC, Number of chips upper limit: 5Cells
Applicable products: fuel cell single cells, membrane electrodes, carbon paper, etc
Applicable standards:
GB/T 20042.5-2009
GB/T 28817-2012
GB/T 31886.1-2015
GB/T 31886.2-2015
GB/Z 27753-2011
Test items: polarization curve of fuel cell single cell/membrane electrode, hydrogen permeation current density, activation polarization overpotential and Ohmic polarization overpotential, electrochemical active area, steady-state test, IV characteristics, IR measurement, limit current, diffusion gain, sensitivity, overload test, impurity influence test, etc
CNAS capabilities: steady-state testing, I-V characteristics, IR measurement, limit current testing, diffusion gain testing, gas metering ratio testing, temperature influence, pressure influence, humidity influence, fuel composition testing, overload testing, long-term operation testing, start/stop cycle testing, loading cycle testing, impurity influence testing